| Operating voltage |
|
| LSN part |
15 V DC to 33 V DC |
| Other expansion module functions |
9 V DC to 30 V DC |
| Current consumption |
|
| LSN part |
4.95 mA |
| Other expansion module functions |
- Max. 370 mA at + 12 V- Max. 180 mA at + 28 V |
| Primary lines PL 1 – PL 6 |
|
| Connection options |
6 detector zones can be programmed as hold-up, intrusion, tamper, closure, or entry |
| Terminal resistance |
RE = 12.1 kilohm |
| Interruption voltage |
Approx. 6 V |
| Line resistance |
Max. 100 Ohm |
| Alarm criteria |
± 40% of terminal resistance |
| Response time |
< 200 ms |
| Control outputs S1 - S3 |
|
| Principle |
Open collector, 12 V when active0 V switching |