Dimensions: |
14 cm x 21 cm x 14 cm(5 in. x 7.5 in. x 5 in.) |
Material: |
High impact ABS plastic enclosure |
Operating Temperature: |
-29°C to +49°C (-20°F to +120°F)For UL Certificated installations, 0°C to +49°C (+32°F to +120°F) |
Radio Frequency Interference (RFI) Immunity: |
No alarm or setup on critical frequencies in the range from 26 MHz to 950 MHz at 50 V/m. |
DS794ZE: |
Complies with Environmental Class II (EN50130-5) |
Height: |
5 m (15 ft.) maximum |
Location: |
Surface or corner |
Current Draw: |
18 mA at 12 VDC25 mA at 12 VDC (DS794ZE) |
Voltage (Input): |
6 VDC to 15 VDCZX794Z: Power comes from two-wire Zonex Bus. <0.5 mA nominal, 2 mA in alarm with LEDs enabled. Do not leave Walk Test LEDs enabled. |
Alarm: |
ZX794Z: Signal through POPIT data bus. |
DS794ZE-FRA: Form C Contacts rated at 3.0 W, 125 mA at 28 VDC for resistive loads protected by a 4.7 Ω resistor in the common C leg. |
|
Tamper: |
Normally-closed (with cover in place). Contacts rated at 28 VDC, 125 mA maximum. |
ZX794Z: Signal through POPIT data bus. Signaled as Missing. |
|
Trouble: |
Solid state output, shorts to negative when activated. Maximum current load is 25 mA. |
ZX794Z: Signal through POPIT data bus.
|